K1R143/1L3

Emergency luminaire for single- or double-sided signage. Surface mounted.
impact-resistant polycarbonate
LED
sign plate with dot-matrix • acrylic (PMMA)
250 lm
signage with additional lighting
ESM - wired

CRI 90

Most of our products are also available in CRI (Ra) 90.

Please contact our sales department for more information

LLMF

The figure that reflects the drop in luminous flux of the light source (LLMF) takes into account failing LEDs, and deterioration of the light output over time. How do we determine this LLMF? We distinguish between the service life of LEDs at the component level and at the luminaire level.

At the component level we take into account the gradual deterioration of the luminous flux of the LEDs (parametric failure or B-lifetime), and the potential breakdown of LEDs (catastrophic failure or C-lifetime). At the luminaire level the complete failure of a luminaire is not relevant (see Luminaire Survival Factor). The LLMF corresponds with the B-lifetime at the luminaire level and hence takes on board the parametric as well as catastrophic failure of the individual LEDs in the luminaires.

In order to achieve an accurate, reliable LLMF for our luminaires, we carry out a ‘principal component analysis’:

  • We determine the parametric failure at the component level in accordance with objective LM80/TM21.
  • We are unable to calculate the catastrophic failure, but prefer to collaborate with manufacturers who make accurate data available. Whenever no measurement data are offered, we depend on electronic reliability models (MIL-HBK-217F)

UGR

Unified Glare Rating

This is an approximate model expressing the risk of glare.

The standard values range from UGR 16 (low risk of glare) to UGR 28.
In the standard for workplace lighting EN12464-1, limit values for UGR are imposed for various rooms.

Unified Glare Rating

Quick downloads

x

Tender description

K1R143/1L3 Emergency luminaire for single- or double-sided signage. Surface mounted. Autonomous luminaire (contains battery). Dimensions: 315 mm x 33 mm x 219 mm. Screwless opening, automatic electrical connection, screwless wire terminals (up to 2.5 mm²), suited for ceiling and wall mounting, optional accessories for recessed or suspended mounting. The K1 pictogram can be fitted with additional LEDs at the bottom of the pictogram (L3 option). In the event of a power outage, the discreetly integrated LEDs provide additional escape route lighting, anti-panic lighting or illuminate the fire extinguishers. Lumen output in emergency mode: 250 lm. Power consumption in standby: 2.8 W. Voltage: 220-230V. Autonomy: 60 minutes. The luminaire contains lamp data, battery date and type as required according to EN 60598-2.22. Battery: 4 x NiMh 1,2V 1,1Ah. Battery lifetime: 10 years. Automatic functional test every week, duration every test 13 weeks, in accordance to EN 50172 and EN 62034. Monitoring and control via ESM software for central maintenance. Polarity independent connection via two wire BUS communication. Maintained/non maintained mode selectable, preset for most common application. Electrical insulation class: class II. Photobiological safety IEC/TR 62778: RG0. Impact-resistant polycarbonate housing, RAL9003 - signal white. IP protection level: IP42. IK protection level: IK04. Ambient temperature: 5°C - 35°C. Glowwire: 850°C. 5 years warranty on luminaire, light source, driver and battery (for autonomous luminaires). Certifications: CE. The luminaire has been developed and produced according to standard EN60598-1 in a company that is ISO9001 and ISO14001 certified.