E22/LED4N060D5-ATEX1
CRI 90
A maioria dos nossos produtos também está disponível em CRI (Ra) 90.
Para mais informações, contacte o nosso departamento comercial
LLMF
The figure that reflects the drop in luminous flux of the light source (LLMF) takes into account failing LEDs, and deterioration of the light output over time. How do we determine this LLMF? We distinguish between the service life of LEDs at the component level and at the luminaire level.
At the component level we take into account the gradual deterioration of the luminous flux of the LEDs (parametric failure or B-lifetime), and the potential breakdown of LEDs (catastrophic failure or C-lifetime). At the luminaire level the complete failure of a luminaire is not relevant (see Luminaire Survival Factor). The LLMF corresponds with the B-lifetime at the luminaire level and hence takes on board the parametric as well as catastrophic failure of the individual LEDs in the luminaires.
In order to achieve an accurate, reliable LLMF for our luminaires, we carry out a ‘principal component analysis’:
- We determine the parametric failure at the component level in accordance with objective LM80/TM21.
- We are unable to calculate the catastrophic failure, but prefer to collaborate with manufacturers who make accurate data available. Whenever no measurement data are offered, we depend on electronic reliability models (MIL-HBK-217F)
UGR
Unified Glare Rating
Este é um modelo aproximado que expressa o risco de brilho.
Os valores padrão variam de UGR 16 (baixo risco de brilho) a UGR 28. Na norma EN12464 para iluminação de locais de trabalho, são impostos valores-limite para UGR para várias divisões.
Transferências rápidas
Dados fotométricos
- DIALux ULD
- Eulumdat LDT
Descrição cadernos de encargos
- Descrição cadernos de encargos
- Descrição cadernos de encargos com foto
Descrição do produto
Folha de dados do produto
Descrição cadernos de encargos
Informação do produto
Medidas
Equipamento eléctrico
Power factor
The power factor is a technical indicator of the driver that shows how closely the current of the waveform approximates the sinusoidal reference of the voltage. The power factor (λ) is composed of two parts:
the shift between voltage and current (cos ϕ) and the distortion of the current (harmonics or Total Harmonic Distortion).
The smaller the shift and distortion of the waveform, the fewer losses and pollution on the energy supplier’s distribution network. In ETAP LED drivers we exclusively work with a power factor in excess of 0.9.
Autonomia
Quando a rede elétrica falha, a iluminação de emergência acende por um determinado período de tempo: a autonomia.
- 60 minutos: adequado para a maioria das aplicações
- 180 minutos: quando a evacuação requer mais tempo, por exemplo em edifícios altos ou centros de atendimento
Índice de circularidade
O índice de circularidade indica o nível de circularidade e sustentabilidade alcançado pelas nossas luminárias.
- A pontuação de circularidade do produto indica até que ponto o nosso produto se enquadra na economia circular baseada nos princípios sem fim, sem esforço e sem desperdício.
- A pontuação de eficiência ao longo da vida útil compara o impacto energético e material da nossa luminária com um produto de referência no mercado.
Através do índice de circularidade, desafiamo-nos a melhorar continuamente os nossos produtos e a alcançar pontuações mais elevadas em termos de circularidade e sustentabilidade.
Consulte todos os pormenores no nosso blogue.
Eprel Data fonte de luz
Tempo de vida
Time(khrs) | LLMF(%) | Cx(%) |
---|---|---|
10 | 99 | 1 |
20 | 98 | 2 |
30 | 98 | 3 |
40 | 97 | 4 |
50 | 96 | 5 |
60 | 96 | 6 |
Dados fotométricos
Intensidades luminosas em cd
Gamma | C0 | C45 | C90 | Gamma | C0 | C45 | C90 |
---|---|---|---|---|---|---|---|
0° | 2393.2 | 2393.2 | 2393.2 | 90° | 267.7 | 144.4 | 1.6 |
5° | 2378.8 | 2366.8 | 2371.5 | 95° | 276.8 | 122.3 | 0.0 |
10° | 2361.0 | 2360.1 | 2328.5 | 100° | 343.9 | 117.7 | 0.0 |
15° | 2328.6 | 2306.4 | 2268.8 | 105° | 313.3 | 114.7 | 0.0 |
20° | 2387.9 | 2246.3 | 2203.1 | 110° | 190.6 | 113.2 | 0.0 |
25° | 2481.2 | 2264.4 | 2120.6 | 115° | 115.0 | 92.9 | 0.0 |
30° | 2533.8 | 2310.7 | 2022.5 | 120° | 74.6 | 56.0 | 0.0 |
35° | 2700.5 | 2290.4 | 1888.1 | 125° | 49.2 | 29.1 | 0.0 |
40° | 1864.3 | 2367.2 | 1737.8 | 130° | 31.6 | 9.3 | 0.0 |
45° | 1134.4 | 1830.7 | 1562.3 | 135° | 18.7 | 1.0 | 0.0 |
50° | 785.0 | 1173.6 | 1386.8 | 140° | 2.0 | 0.0 | 0.0 |
55° | 584.0 | 772.0 | 1179.2 | 145° | 0.0 | 0.0 | 0.0 |
60° | 452.3 | 539.4 | 916.1 | 150° | 0.0 | 0.0 | 0.1 |
65° | 378.2 | 395.9 | 633.5 | 155° | 0.0 | 0.0 | 0.0 |
70° | 318.9 | 307.5 | 393.5 | 160° | 0.0 | 0.0 | 0.0 |
75° | 286.3 | 245.4 | 220.7 | 165° | 0.0 | 0.0 | 0.0 |
80° | 268.3 | 201.6 | 104.3 | 170° | 0.1 | 0.1 | 0.3 |
85° | 260.2 | 165.9 | 26.1 | 175° | 0.0 | 0.0 | 0.0 |
90° | 267.7 | 144.4 | 1.6 | 180° | 0.0 | 0.0 | 0.0 |
Luminância
Gamma | C0 | C30 | C45 | C60 | C90 |
45° | 16826 | 21689 | 29857 | 33996 | 33547 |
50° | 12090 | 14581 | 20127 | 28768 | 32757 |
55° | 9430 | 10842 | 14072 | 21794 | 31216 |
60° | 7736 | 8722 | 10579 | 16204 | 27819 |
65° | 6932 | 7341 | 8471 | 12063 | 22761 |
70° | 6347 | 6730 | 7301 | 9256 | 17467 |
75° | 6288 | 6346 | 6600 | 7455 | 12949 |
80° | 6629 | 6232 | 6305 | 6405 | 9120 |
85° | 7410 | 6622 | 6257 | 5817 | 4548 |
UGR
Corrected Glare Ratings for a Total Lamp Flux of 6650lm (S = 0.25H)
Room Reflection Factors (%) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ceiling Walls Floor |
70 50 20 |
70 30 20 |
50 50 20 |
50 30 20 |
30 30 20 |
70 50 20 |
70 30 20 |
50 50 20 |
50 30 20 |
30 30 20 |
Room Dimensions | Viewed Crosswise | Viewed Endwise | ||||||||
X = 2H Y = 2H | 20.1 | 21.7 | 20.5 | 22.1 | 22.4 | 23.4 | 25.0 | 23.8 | 25.4 | 25.8 |
Y = 3H | 20.7 | 22.1 | 21.1 | 22.5 | 22.9 | 24.2 | 25.7 | 24.6 | 26.1 | 26.5 |
Y = 4H | 21.0 | 22.4 | 21.5 | 22.8 | 23.2 | 24.4 | 25.8 | 24.9 | 26.2 | 26.6 |
Y = 6H | 21.5 | 22.8 | 22.0 | 23.2 | 23.6 | 24.5 | 25.8 | 25.0 | 26.2 | 26.6 |
Y = 8H | 21.8 | 23.1 | 22.3 | 23.5 | 23.9 | 24.5 | 25.7 | 25.0 | 26.2 | 26.6 |
Y = 12H | 22.2 | 23.3 | 22.6 | 23.8 | 24.2 | 24.5 | 25.6 | 24.9 | 26.1 | 26.5 |
X = 4H Y = 2H | 20.4 | 21.8 | 20.9 | 22.2 | 22.6 | 23.4 | 24.7 | 23.8 | 25.1 | 25.5 |
Y = 3H | 21.2 | 22.4 | 21.7 | 22.8 | 23.3 | 24.3 | 25.5 | 24.8 | 25.9 | 26.3 |
Y = 4H | 21.7 | 22.8 | 22.2 | 23.2 | 23.7 | 24.6 | 25.6 | 25.1 | 26.1 | 26.6 |
Y = 6H | 22.4 | 23.3 | 22.9 | 23.8 | 24.3 | 24.8 | 25.7 | 25.3 | 26.2 | 26.7 |
Y = 8H | 22.8 | 23.7 | 23.3 | 24.2 | 24.7 | 24.8 | 25.7 | 25.4 | 26.2 | 26.7 |
Y = 12H | 23.3 | 24.1 | 23.8 | 24.6 | 25.1 | 24.8 | 25.6 | 25.4 | 26.1 | 26.7 |
X = 8H Y = 4H | 22.0 | 22.8 | 22.5 | 23.3 | 23.8 | 24.6 | 25.5 | 25.1 | 26.0 | 26.5 |
Y = 6H | 22.8 | 23.5 | 23.4 | 24.1 | 24.6 | 24.9 | 25.6 | 25.5 | 26.2 | 26.7 |
Y = 8H | 23.4 | 24.0 | 23.9 | 24.6 | 25.1 | 25.0 | 25.6 | 25.6 | 26.2 | 26.8 |
Y = 12H | 24.0 | 24.6 | 24.6 | 25.1 | 25.7 | 25.0 | 25.6 | 25.6 | 26.2 | 26.8 |
X = 12H Y = 4H | 22.0 | 22.8 | 22.5 | 23.3 | 23.8 | 24.6 | 25.4 | 25.2 | 25.9 | 26.4 |
Y = 6H | 22.9 | 23.5 | 23.5 | 24.1 | 24.6 | 24.9 | 25.6 | 25.5 | 26.1 | 26.7 |
Y = 8H | 23.5 | 24.1 | 24.1 | 24.6 | 25.2 | 25.1 | 25.6 | 25.6 | 26.2 | 26.8 |
UGR Variations with Observer Position for Luminaire Spacings S | ||||||||||
S = 1.0H | +0.6 | -0.6 | +0.4 | -0.3 | ||||||
S = 1.5H | +0.9 | -0.9 | +0.6 | -0.8 | ||||||
S = 2.0H | +1.5 | -1.1 | +1.5 | -1.8 |
Eficiência
Room Reflection Factors (%) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ceiling Walls Floor |
80 50 20 |
80 30 20 |
80 10 20 |
50 50 20 |
50 30 20 |
50 10 20 |
30 50 20 |
30 30 20 |
30 10 20 |
0 0 0 |
RCR = 1 | 103 | 100 | 98 | 95 | 93 | 91 | 90 | 88 | 87 | 80 |
2 | 91 | 86 | 82 | 84 | 80 | 77 | 80 | 76 | 74 | 68 |
3 | 80 | 74 | 70 | 74 | 70 | 66 | 71 | 67 | 64 | 59 |
4 | 72 | 65 | 60 | 67 | 61 | 57 | 64 | 59 | 55 | 51 |
5 | 65 | 57 | 52 | 60 | 54 | 50 | 58 | 53 | 49 | 45 |
6 | 59 | 51 | 45 | 55 | 49 | 44 | 53 | 47 | 43 | 40 |
7 | 53 | 46 | 40 | 50 | 44 | 39 | 48 | 42 | 38 | 35 |
8 | 49 | 41 | 36 | 46 | 39 | 35 | 44 | 38 | 34 | 32 |
9 | 45 | 37 | 32 | 42 | 36 | 31 | 41 | 35 | 31 | 29 |
10 | 41 | 34 | 29 | 39 | 33 | 29 | 38 | 32 | 28 | 26 |
Room Reflection Factors (%) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ceiling Walls Floor |
80 50 30 |
80 30 30 |
80 50 10 |
50 30 10 |
50 50 30 |
50 30 30 |
50 50 10 |
50 30 10 |
30 30 10 |
0 0 0 |
k = 0.60 | 50 | 41 | 48 | 40 | 47 | 40 | 45 | 39 | 38 | 32 |
0.80 | 62 | 53 | 58 | 51 | 58 | 51 | 55 | 49 | 48 | 41 |
1.00 | 70 | 61 | 65 | 58 | 65 | 58 | 62 | 56 | 55 | 48 |
1.25 | 80 | 71 | 73 | 67 | 74 | 67 | 70 | 64 | 63 | 56 |
1.50 | 86 | 78 | 78 | 72 | 79 | 73 | 74 | 70 | 68 | 61 |
2.00 | 94 | 87 | 84 | 79 | 86 | 80 | 80 | 76 | 74 | 67 |
2.50 | 101 | 94 | 89 | 84 | 91 | 86 | 84 | 81 | 78 | 72 |
3.00 | 105 | 99 | 92 | 88 | 95 | 91 | 88 | 85 | 82 | 76 |
4.00 | 110 | 105 | 95 | 92 | 99 | 95 | 90 | 88 | 85 | 79 |
5.00 | 114 | 109 | 98 | 95 | 102 | 98 | 93 | 90 | 88 | 82 |