R710R1/LEDN2430SX1
surface-mounted luminaire
•
linear
Office, Healthcare, Education, Horeca, Retail, Leisure
lacquered sheet steel
high power LED
•
4000 K
LED+LENS™
•
polycarbonate (PC) lens and cup
•
medium wide-angle
<= 16
3100 lm
129 lm/W
98% @ 50khrs (Tq=25°C)
EN 62471: RISK GROUP 1 UNLIMITED
Quick downloads
Photometric data
- DIALux ULD
- Eulumdat LDT
Tender description
- Tender description
- Tender description with picture
Product description
Product data sheet
- Accessories
- Others
x
Product description
R710R1/LEDN2430SX1
Linear surface-mounted luminaire, LED+LENS™ optics, polycarbonate (PC) lens and cup, medium wide-angle light distribution.
Dimensions: 1500 mm x 150 mm x 50 mm.
Housing with a visible height of 15 mm and seamless square corners. Lenses recessed in circular cups.
LED+LENS™, a combination of high-power LEDs and individual lenses with a patented surface structure. The lenses are recessed in small cups for a comfortable light experience.
Luminous flux: 3100 lm, Luminous efficacy: 129 lm/W.
Power: 24.0 W, not dimmable.
Frequency: 50-60Hz AC.
Voltage: 220-240V.
Electrical isolation class: class I.
LED with very good light maintenance; at 50000 hrs the luminaire retains 98% of its initial flux (Tq=25°C).
Correlated colour temperature: 4000 K, Colour rendering ra: 80.
Standard deviation colour matching satisfy 3 SDCM.
LED+LENS™ for glare-free light distribution with UGR <= 16 and luminances @ 65° 1000 Cd/m² conform norm EN 12464-1 for very high visual demands, e.g. quality control, precision tasks.
Photobiological safety EN 62471: RISK GROUP 1 UNLIMITED.
Lacquered sheet steel housing, RAL9003 - white (textured).
IP protection level: IP20.
Glowwire: 850°C.
5 years warranty on luminaire and driver.
Certifications: CE, ENEC.
Luminaire with halogen free leads.
The luminaire has been developed and produced according to standard EN60598-1 in a company that is ISO9001 and ISO14001 certified.
Product info
Mechanical properties
1500 mm x 150 mm x 50 mm
RAL9003 - white (textured)
individual luminaire
IP20
EER Design
No
No
Light source
4000 K
80
Electrical Properties
not dimmable
24 W
220-240V
50-60Hz AC
Dimensional drawing
Photometric data
3100 lm
129 lm/W
1000 cd/m²
24 W
16
98% @ 50khrs (Tq=25°C)
4000 K
80
Luminous intensities in cd
Gamma | C0 | C45 | C90 |
---|---|---|---|
0° | 1908.5 | 1908.5 | 1908.5 |
5° | 1958.9 | 1957.6 | 1967.6 |
10° | 1902.7 | 1911.7 | 1920.2 |
15° | 1854.4 | 1870.2 | 1886.6 |
20° | 1824.3 | 1837.7 | 1864.7 |
25° | 1801.9 | 1818.1 | 1839.2 |
30° | 1727.2 | 1776.6 | 1776.2 |
35° | 1425.3 | 1497.5 | 1538.8 |
40° | 958.6 | 990.3 | 1043.5 |
45° | 571.1 | 568.4 | 612.6 |
50° | 255.3 | 253.8 | 297.1 |
55° | 122.5 | 115.7 | 133.5 |
60° | 62.3 | 61.5 | 66.6 |
65° | 37.1 | 36.3 | 40.3 |
70° | 23.8 | 23.5 | 25.7 |
75° | 15.3 | 15.1 | 16.4 |
80° | 8.6 | 8.6 | 10.2 |
85° | 3.0 | 3.0 | 4.2 |
90° | 0.5 | 0.7 | 1.1 |
Luminance
3100 lm
129 lm/W
1000 cd/m²
0.12 m²
Gamma | C0 | C30 | C45 | C60 | C90 |
45° | 6868 | 7278 | 6836 | 7359 | 7366 |
50° | 3378 | 3587 | 3357 | 3689 | 3930 |
55° | 1816 | 1790 | 1715 | 1878 | 1979 |
60° | 1060 | 1107 | 1046 | 1132 | 1132 |
65° | 747 | 783 | 731 | 781 | 811 |
70° | 593 | 613 | 585 | 614 | 640 |
75° | 502 | 519 | 496 | 537 | 539 |
80° | 423 | 456 | 421 | 462 | 497 |
85° | 290 | 362 | 290 | 364 | 410 |
UGR
Corrected Glare Ratings for a Total Lamp Flux of 3100lm (S = 0.25H)
Room Reflection Factors (%) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ceiling Walls Floor |
70 50 20 |
70 30 20 |
50 50 20 |
50 30 20 |
30 30 20 |
70 50 20 |
70 30 20 |
50 50 20 |
50 30 20 |
30 30 20 |
Room Dimensions | Viewed Crosswise | Viewed Endwise | ||||||||
X = 2H Y = 2H | 15.4 | 17.0 | 15.7 | 17.2 | 17.5 | 15.5 | 17.0 | 15.8 | 17.3 | 17.5 |
Y = 3H | 15.3 | 16.7 | 15.7 | 16.9 | 17.2 | 15.4 | 16.7 | 15.7 | 17.0 | 17.3 |
Y = 4H | 15.3 | 16.5 | 15.6 | 16.8 | 17.1 | 15.3 | 16.6 | 15.7 | 16.9 | 17.2 |
Y = 6H | 15.2 | 16.4 | 15.6 | 16.7 | 17.0 | 15.3 | 16.4 | 15.6 | 16.7 | 17.0 |
Y = 8H | 15.2 | 16.3 | 15.6 | 16.6 | 16.9 | 15.3 | 16.3 | 15.6 | 16.7 | 17.0 |
Y = 12H | 15.2 | 16.2 | 15.5 | 16.5 | 16.9 | 15.2 | 16.3 | 15.6 | 16.6 | 16.9 |
X = 4H Y = 2H | 15.3 | 16.5 | 15.6 | 16.8 | 17.1 | 15.3 | 16.5 | 15.7 | 16.8 | 17.1 |
Y = 3H | 15.2 | 16.2 | 15.6 | 16.6 | 16.9 | 15.2 | 16.3 | 15.6 | 16.6 | 16.9 |
Y = 4H | 15.2 | 16.1 | 15.6 | 16.4 | 16.8 | 15.2 | 16.1 | 15.6 | 16.5 | 16.8 |
Y = 6H | 15.1 | 15.9 | 15.5 | 16.3 | 16.7 | 15.2 | 16.0 | 15.6 | 16.4 | 16.8 |
Y = 8H | 15.1 | 15.8 | 15.5 | 16.2 | 16.7 | 15.2 | 15.9 | 15.6 | 16.3 | 16.7 |
Y = 12H | 15.1 | 15.7 | 15.5 | 16.2 | 16.6 | 15.1 | 15.8 | 15.6 | 16.2 | 16.7 |
X = 8H Y = 4H | 15.1 | 15.8 | 15.5 | 16.2 | 16.6 | 15.1 | 15.9 | 15.6 | 16.3 | 16.7 |
Y = 6H | 15.1 | 15.7 | 15.5 | 16.1 | 16.6 | 15.1 | 15.7 | 15.6 | 16.2 | 16.6 |
Y = 8H | 15.0 | 15.6 | 15.5 | 16.0 | 16.5 | 15.1 | 15.6 | 15.6 | 16.1 | 16.6 |
Y = 12H | 15.0 | 15.5 | 15.5 | 16.0 | 16.5 | 15.1 | 15.5 | 15.6 | 16.0 | 16.5 |
X = 12H Y = 4H | 15.0 | 15.7 | 15.5 | 16.1 | 16.6 | 15.1 | 15.8 | 15.5 | 16.2 | 16.6 |
Y = 6H | 15.0 | 15.6 | 15.5 | 16.0 | 16.5 | 15.1 | 15.6 | 15.5 | 16.1 | 16.6 |
Y = 8H | 15.0 | 15.5 | 15.5 | 16.0 | 16.5 | 15.1 | 15.5 | 15.5 | 16.0 | 16.5 |
UGR Variations with Observer Position for Luminaire Spacings S | ||||||||||
S = 1.0H | +2.6 | -5.6 | +2.5 | -5.8 | ||||||
S = 1.5H | +4.7 | -7.7 | +4.7 | -7.6 | ||||||
S = 2.0H | +6.6 | -8.6 | +6.7 | -8.6 |
Efficiency
Room Reflection Factors (%) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ceiling Walls Floor |
80 50 20 |
80 30 20 |
80 10 20 |
50 50 20 |
50 30 20 |
50 10 20 |
30 50 20 |
30 30 20 |
30 10 20 |
0 0 0 |
RCR = 1 | 109 | 107 | 106 | 103 | 101 | 100 | 99 | 98 | 97 | 91 |
2 | 100 | 96 | 93 | 94 | 92 | 90 | 91 | 89 | 87 | 83 |
3 | 91 | 86 | 83 | 87 | 83 | 80 | 84 | 81 | 79 | 75 |
4 | 84 | 78 | 74 | 80 | 76 | 72 | 78 | 74 | 71 | 68 |
5 | 77 | 71 | 66 | 74 | 69 | 65 | 72 | 68 | 64 | 62 |
6 | 71 | 64 | 60 | 68 | 63 | 59 | 67 | 62 | 59 | 56 |
7 | 66 | 59 | 54 | 63 | 58 | 54 | 62 | 57 | 53 | 51 |
8 | 61 | 54 | 50 | 59 | 53 | 49 | 58 | 53 | 49 | 47 |
9 | 57 | 50 | 46 | 55 | 49 | 45 | 54 | 49 | 45 | 43 |
10 | 53 | 46 | 42 | 51 | 46 | 42 | 50 | 45 | 42 | 40 |
Room Reflection Factors (%) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ceiling Walls Floor |
80 50 30 |
80 30 30 |
80 50 10 |
50 30 10 |
50 50 30 |
50 30 30 |
50 50 10 |
50 30 10 |
30 30 10 |
0 0 0 |
k = 0.60 | 65 | 57 | 62 | 56 | 63 | 56 | 60 | 55 | 55 | 50 |
0.80 | 77 | 69 | 72 | 66 | 74 | 68 | 70 | 66 | 65 | 60 |
1.00 | 84 | 77 | 78 | 73 | 81 | 75 | 76 | 72 | 71 | 67 |
1.25 | 94 | 87 | 86 | 82 | 89 | 84 | 84 | 80 | 80 | 75 |
1.50 | 99 | 93 | 90 | 86 | 94 | 89 | 88 | 84 | 84 | 79 |
2.00 | 106 | 100 | 94 | 91 | 99 | 95 | 92 | 89 | 88 | 84 |
2.50 | 111 | 105 | 98 | 95 | 103 | 99 | 95 | 93 | 92 | 88 |
3.00 | 115 | 110 | 100 | 98 | 106 | 103 | 98 | 96 | 95 | 91 |
4.00 | 118 | 114 | 102 | 100 | 108 | 105 | 99 | 97 | 96 | 92 |
5.00 | 120 | 117 | 103 | 102 | 110 | 108 | 100 | 99 | 98 | 94 |
Lifetime
Time(khrs) | LLMF(%) | Cx(%) |
---|---|---|
10 | 100 | 2 |
20 | 99 | 4 |
30 | 99 | 6 |
40 | 99 | 8 |
50 | 98 | 10 |
60 | 98 | 12 |
Classifications
818 / 980 / 997 / 1000 / 1000
0.82 / 0.98 / 1.00 / 1.00 / 1.00
BZ1
Symmetrical
A60 (Nach Arbeitsblatt 7)
Phi u = 1.00
Phi su = 0.75
1.00 B + 0.00 T
References
Downloads
General data
Product data
Tender description with picture (docx)
20.92 KB
/pdf/product/34131
Datasheet
Product description with picture (docx)
21.38 KB
Manuals
Models
Photometric data